Annexin V cell-death staining master mixes

Flow cytometryLiterature recipe

A5-FITC master mixes with either TO-PRO-3 or optional 7-AAD for the cited cell-death flow-cytometry assay.

Applicable scenario

Fresh staining of the separately prepared cell samples in the Jiang et al. apoptosis/necrosis workflow. Add 100 µL master mix to 100 µL sample. Choose the TO-PRO-3 route or the optional 7-AAD route according to the assay and analysis plan; do not treat them as sequential steps.

Import to Workspace
QR code to import Annexin V cell-death staining master mixes into Listen Step Workspace

Open or scan to import into Workspace, jump to Modules and open this Recipe in the editor.

Import to the Android App instead · Download Recipe JSON

Formulation tables

A5-FITC/TO-PRO-3 master mix, 100 µL

ComponentMaster-mix concentrationAmount for 100 µL
A5 binding buffer, 10×2×20 µL
A5-FITC1:1001 µL
TO-PRO-31 µMVolume from actual stock
Water or compatible diluentTo volumeTo 100 µL

A5-FITC/7-AAD master mix, 100 µL

ComponentMaster-mix concentrationAmount for 100 µL
A5 binding buffer, 10×2×20 µL
A5-FITC1:1001 µL
7-AAD (optional route)2 µg/mLVolume from actual stock
Water or compatible diluentTo volumeTo 100 µL

Source values and calculations

Literature source

Jiang L et al. Monitoring the progression of cell death and the disassembly of dying cells by flow cytometry. Nature Protocols 11, 655–663 (2016).

Source locator: Reagent setup, p. 659, A5-FITC/TO-PRO-3 staining master mix; Procedure steps 5–6

Read the original source · DOI: 10.1038/nprot.2016.028

Editorial source check: 2026-11-09. Verify the original publication, actual stock concentrations and local safety requirements before use. Research use only; not clinical instructions.